Alat Laboratorium Lingkungan Pertanian dan Survey

Posted on by

Hygrometer Digital

Hygrometer DigitalHygrometer Digital
Untuk Mengetahui Kelembaban dan Temperature Ruangan
Mempunyai dua sensor :
Sensor Humidity dan Temperature dan Sensor Temperature type K
Temperature Range : -10ºC to 50ºC
K-type range : -20ºC to 1,000ºC
Relative humidity range : 5.0% to 98% rH
Accuracy :
Temperature ± 1ºC
rH : ± 3%
Resolusi :
Temperature ± 0.1ºC
K-type : 1ºC
rH : 0.1%rH
Operation Condition : -10ºC to 50ºC
Large LCD
Humidity and Temperature Measuring
Humidity and Temperature Max / Min Measuring
Data Hold
ºC or ºF selectable
Low battery indication,Autopower off,LCD back light
K-type thermocouple


Sling Hygrometer

Sling HygrometerSling Hygrometer
Untuk Mengetahui Kelembaban dan Temperature Ruangan
Range : -5°C to +50°C,
Having 2 red liquid thermometer, wet and dry
graduated every 1/2°, Red Liquid
Automatic wick wetting, Sensitive thermometers store.
Built-in slide rule scales for determining relative humidity.
Pocket-sized, 7-1/2″L, 1″ diameter

 


Alat Ukur Kebisingan

Alat Ukur KebisinganAlat Ukur Kebisingan
IntellSafe – SOUND LEVEL METER – KMAR814
Alat ukur tingkat kebisingan Suara
Designed according to IEC651, Type 2, ANSI S1.4 Type 2
CE and ISO 9001,AC/DC Output,Auto Power Shut Off
Low Battery Display,Over Range Indication
Sound Measuring Level Selection,Max Hold Function
Designed to meet the measurement of Safety Engineer, Health, Industrial Safety Officer and Sound Quality Control in various environment
Measuring Range
Range :30~130dB A , ±1,5 dB
Range :35~130dB C
Bar Graph : 50dB scale at 1dB step monitoring
Time Weighting Selection:
Fast for normal measurement
Slow for checking AVERAGE level of fluctuating noise
Frequency Weighting :
A weighting for general sound level measurement
C weighting for checking low frequency content of noise
Microphone :1/2 Inch Electret Condenser Microphone
Sampling Frequency : 2 times/sec


Infrared Thermometer

Infrared ThermometerInfrared Thermometer
Temperature Range :-32ºc to 530ºC (ºC and ºF)
Accuracy : ± 2% + 2ºC
Distance Spot Ratio : 12 : 1
Emissivity : 0.95
Resolution : 0.1ºC / ºF
Response time & Wavelength : 500 ms
ºC / ºF Selection : Yes
Power : Alkaline 9Volt
Weight (Approximately) : 145 x 130 x 38
Size : 145x130x38mm


Portable pH / Temperature Meter

Portable pH / Temperature Meter

pH Meter Oakton USA
ph : 0.00 to 14.00 pH;
Temperature : 0.0 to 100.0°C.
Resolution: 0.01 pH; 0.1°C.
Accuracy: ±0.01 pH; ±0.5°C.
Calibration: Up to 3 Buffer Values (pH 4.01, 7.00; 10.0).

Display: Single Custom LCD. Auto Shut-Off: After 17 minutes.
Operating Temp.: 32°F to 122°F (0°C to 50°C).
Temp. Compensation: Automatic Temperature Compensation (ATC) Fixed 2% per °C factor.
Power: Four AAA alkaline batteries (supplied) >60 hours continuous use.


Dissolved Oxygen Meter

Dissolved Oxygen Meter DO Meter Oakton USA
DO Range : 0.00 to 20.00 mg/L (ppm), 0.0 to 200.0%,
Temperature Range : -5.0°C to 105.0°C.
Resolution: 0.01 mg/L (ppm), 0.1%, 0.1°C.
Accuracy: ±1.5% full-scale, ±0.5°C.
Operating Temp: 0 to 50°C
Power: Four 1.5V AAA batteries
Battery Life: >700 hours continuous use.

 


Portable Conductivity Meter

Portable Conductivity MeterPortable Conductivity Meter, Oakton USA
Specifications
Range:
Conductivity Range : 0 to 20.0µS; 0 to 200.0µS; 0 to 2,000µS; 0 to 20.00mS; 0 to 200.0 mS;
Temperature : -10.0°C to 110.0°C.
Resolution: 0.01µS; 0.1 µS; 1 µS; 0.01mS; 0.1mS; 0.1°C.
Accuracy: ±1% full scale; ±0.5°C. Calibration: 1 to 5 points (push button: 1 point per range).
Display: Single Custom LCD;
Auto Shut-Off: After 17 minutes;
Operating Temperature: 0°C to 50°C


Turbidity Meter

Turbidity Meter Turbidity Meter USA
Range: 0 up to 1,100 NTU.
Accuracy: from 0 NTU to 500 NTU, ±2% of reading or ±0.01 NTU
Accuracy: from 500 to 1,100 NTU, ±3% of reading.
Resolution: below 10 NTU approx 0.01 NTU from 10 to 100 NTU approx 0.1 NTU ; from 100 to 1,100 NTU approx 1 NTU.
Response Time: approx 6 up to 16 seconds.
Display : 4 digit LCD.
Power Supply: 4 AAA batteries.
Battery Life: 1,000 and above tests


Pocket PH Meter and Temperature Meter

Pocket PH Meter and Temperature MeterPocket PH Meter and Temperature Meter
Range : -2.0 to 16.0 pH
Temp : -5.0 to 60.0°C
Resolution pH : ±0.1 pH
Temp : 0.1°C
Accuracy pH : ±0.1 pH
Temp : ±0.5°C

 


UV Spectrophotometer

UV SpectrophotometerWavelength Range : 200 ~ 800 nm
Wavelength Accuracy : ± 2 nm
Wavelength Repeat : 0.5 nm
T-A Change Accuracy : ± 0.004A
Transmittance Accuracy : ± 0.5%
Transmittance Repeat : 0.5%
Spectrum band width : 6 nm
Stability : 0.5% within 3 minutes
Mixed light : 0.5%

 


UV-VIS Spectrophotometer

UV-VIS Spectrophotometer UV-VIS Spectrophotometer
Specification:
Wavelength Range 200~1000nm
Wavelength Accuracy =2nm
Wavelength Repeatability =1nm
Transmittance Accuracy ±0.5%(t) (NBS930D)
Transmittance Repeatability =0.2%(f)
Spectrum Bandwidth 4nm
Stray Light =0.3%(t) (at 220nm, NaI)
Light Current Drift 0.5%(t)/3min
Dark Current Drift 0.2%(t)/3min
Cell Holder 5cm


Compass dan Altimeter

Compass dan AltimeterCompass dan Altimeter
Altimeter from -700 meters to 9000 meters
Barometer from 300 mb/hPa to 1100 mb/hPa
Compass 16 cardinal directions and bearing in degrees (one degree resolution)
Time Displays year, month, day/date, hour, minute and seconds.
Chronograph 1/100-second resolution up to 24 hours.

 


Compass

CompassKompas
Azimut : 0 to 360 Derajat
Base Magnifier
mm scale

 

 

 


Clinometer

ClinometerClinometer
Untuk mengukur kemiringan
Mengukur dalam meter serta sudut pengukuran
Accuracy : ±0.2′ : ±0.2Deg

 

 

 


Rangefinder

RangefinderRangefinder
Untuk mengukur range, tinggi dan sudut pengukuran
Range : 10 sampai 500 m
6 x perbesaran

 

 

 


Weather Station

Weather Station

Alat Pemantau Cuaca
Wireless sends data up to 1,000 feet (300 m)
Opsi :software (sold separately) untuk weather analysis dan data storage.

Temperature – Range:
Inside Temperature 0° to +60°C
Outside Temperature, -40° to +65°C
Accuracy: Inside Temp.±0.5°C, Outside Temp ±0.5°C-7°C
Humidity :
Range: 1 to 100% RH.
Resolution: 1%.
Accuracy: ±3% (0 to 90% RH), ±4% (90 to 100% RH).
Barometric Pressure –
Range: 16.00” to 32.50” Hg, 410 to 820 mm Hg, 540 to 1100.0 hPa/mb.
Resolution: 0.01” Hg, 0.1 mm Hg, 0.1 hPa/mb.
Accuracy: ±0.03” Hg (±0.8 mm Hg, ±1.0 hPa/mb).
Wind Speed –
Range: 1 to 80 m/s
Resolution: 0.5 m/s
Accuracy: 1 m/s, ±5%, whichever is greater.
Wind Direction –
Range: 0-360°.
Resolution: 16 points (22.5°) on compass rose.
Accuracy: ±3°.
Wind Chill –
Range -79° to +57°C
Resolution: 1°. Accuracy:±1°C
Rainfall –
Range: 0 to 6553 mm
Resolution: 0.2 mm.
Accuracy: Greater of 4% or 1 tip